Important Data Center Metrics You Should Know

               We all know that data center and both mechanical and electronic equipment within the facility are becoming energy efficient. There are a variety of standards, certificates and metrics that have emerged to measure the efficiency of the facility. Metrics and Standards are very important to perform accurate measurement of data center and its IT equipment. Standards and Certification programs can maintain the integrity of IT companies’ claims for energy efficiency. Following are some of the certifications, standards and metrics that companies are using to show the energy efficiency of their facility and equipment.

Carbon Intensity per Unit Data:

               Carbon Intensity is used to refer the ratio of carbon-di-oxide to energy. It is a measurement of the amount of carbon emissions per unit of fuel consumed. Akamai is one of the leading content delivery network has been reporting carbon emission related to cloud computing. Carbon emission related to cloud computing based services in the metrics of “CO2/ megabytes of data transferred”. This metric enables Akamai to compare cloud computing usage across industry and also in process of making this metric to available on a monthly basis to its clients. Greenpeace has praised Akamai for its transparent reporting of this metrics and has awarded highest grade for its transparency above all giant internet players like Apple, Google, Facebook and, IBM.

Power Usage Effectiveness (PUE):

                This is the leading metrics which shows how efficiently the data center is operating. PUE is the ratio of how much energy is consumed in running data center’s equipment to the energy consumed to run the overall data center. This metric was created by “The Green Grid”. If a data center consumes lot of energy for cooling and power conversion, the facility isn’t very efficient and its PUE rating will be very near to 2. If very little energy is consumed in power conversion and cooling then data center will have a PUE closer to one.

Leadership in Energy and Environmental Design (LEED):

                This is a certificate awarded by the U.S. Green Building Council. LEED council evaluates green credentials of the building and consider several factors like materials, water used, indoor environmental quality and, location along with the efficiency of the plant to award any one of the five certificates certified by U.S. Green Building Council.

American Society of Heating, Refrigerating and Air- Conditioning Engineers (ASHARE):

                This society is focused on building systems, indoor air quality, and sustainability, refrigeration and energy efficiency. ASHARE also publishes a series of standards and guidelines relating to HVAC (Heating, Ventilation, and Air-Conditioning) issues and

systems.

Energy Star:

                Environmental Protection Agency (EPA)’s energy star certification is one of the widely used certification program for computers and gadgets. This certification can also be used for data centers and building that runs many number of data centers.

PAR4:

                This metric measures server powers in different methods including peak power, transaction per watt, idle power and total utilization of power.PAR4 metric is developed my startup power Assure and enables servers of different generations

to one another in terms of energy consumption and efficiency. PAR4 is gaining huge response from Internet giants like Cisco, Intel and, Dell and have been working to incorporate this metric into their systems.

 

Data Center Talk updates its resources everyday. Visit us to know of the latest technology and standards from the data center world.

Please leave your views and comments on DCT Forum

Share on TwitterSubmit to StumbleUpon

Tips for securing your Big Data

               In IT industry Big Data is a collection of large data sets which are hard to manage on hand base management tools. Some of the challenges faced in managing big data are storage, curation, capture, analysis, visualization and search. Big data are difficult to manage using desktop packages, instead massive software running on several tens or thousands of servers. Demand for maintaining big data has increased especially in the field of telecommunication and IT. Some of the big data maintaining giants are IBM, HP, SAP, Oracle Corporation and Microsoft. Following are some of the tips which I came across for securing big data.

Plan about Securing Data before Starting Big Data Project

                Technicians should involve in protecting big data before installing or feeding data. Organizations need to find alternative ways to secure big data. Organizations should have serious discussions about data security and other related security issues.

Have A Clear Idea About What Data May Get Stored:

                Data incorporated into Hadoop for storing and running are subjected to specific security measures. Every organization faces huge risk or implementing security for data transfer and usage. So companies need to have a look at revenue loss and risk associated with leakage.

Centralize your account:

                Data are organized so vividly, sometimes data reside in diverse organizations. To ensure consistency in data access and for better policy enforcement, centralize the data account.

Separate Encrypted Data and Encryption Keys:

                Maintaining same server for storing both encrypted data and encryption keys is like locking the door and leaving the keys in lock socket. Key management system will allow users to store encryption keys and encrypted data separately.

Use Encryption for Both Data in Motion and At Rest:

                If companies plan to implement SSL encryption, this can protect data as it moves from applications and nodes. Encryption of data will protect malicious administrators or users to gain access to data. This is one of the cost effective ways to solve several data security threats.

Use Secure Automation:

                If you are dealing with the multiple node environments, this might hamper deployment consistency. So it’s better to use automation tools which help you to cheap cialis online configure the application, update the stack, certificates, patching and platform.

Use Kerberos Network Authentication Protocol:

                This is one of the effective methods for keeping rouge nodes and application of your cluster. This protocol can help to protect web console access. Kerberos is a painful method to set-up and re-validate new nodes and applications.

Add Log Files To your Cluster:

                Many companies started big data to maintain log files, why not to include log files on-to your clusters? Adding log files will provide you a place to look when you think you have been hacked or when something fails.

Ensure Secure Connectivity Between Nodes and Between Nodes and Applications:

                One of the best methods to ensure secure connectivity is by implementing SSL-TLS. If an organization implements an average built network then it is recommended to integrate the system with stack application.

                Do you agree to these steps, will these steps will help to secure big data in an organizational level.

Data Center Talk updates its resources everyday. Visit us to know of the latest technology and standards from the data center world.

Please leave your views and comments on DCT Forum

Share on TwitterSubmit to StumbleUpon

Data Center Operations and Its Biggest Mistakes

Data Center is a facility furnished with computer system and associated components, such as storage and telecommunication systems. Data centers are drawing attention globally with its unique features li

ke reliability, space for large data, redundancy and temperature control. Data centers generally include data communication connection, power supply backups, security devices, fire suppression and air conditioners. Massive data centers consume electricity as a small town and contribute a significant amount of air pollution in the form of diesel exhaust. Boom of data centers rose during the dot – com bubble. Similarly for years massive data centers are mesmerized to a lot of operational errors, mainly due to human blooper.

To yield better efficiency data centers companies have to ensure operational programs are fully functional and successful. Data centers have to be very watchful to avoid traps. Here are some of the common mistakes happen in data centers:

Relying Too Much on Data Center Design:

We can observe companies investing a lot of money on redundant design of the facility rather than concentrating on their operations. This is one of the best examples for human lackadaisical. Many data centers concentrate more on appointing specialist to design office building maintenance and no experts in managing critical operational facilities.

Disregarding Operation Team in Facility Design:

This is the first step that an organization needs to implement to balance the company’s capital expenditure. This step helps an organization to control and understand company’s operational expenditure. This step also includes determining performance characteristics and design criteria.

Failure in Addressing the Correct Number of Staffs:

Many Hosting companies owning data centers underestimate the need of appropriate staffing. Insufficient staffing can result in havoc at emergency situations. So it’s better to create schedule and deploy proper number of resources.

Failure in Training and Developing Right Talent

Once an organization hires a fresher or a qualified person, it’s important to provide training and support. Generating a positive

environment significantly improves the retention rates of the person. Companies need to have step by step training programs in order to expertise the work assigned to them.

Failing to Test Skills Consistently:

Organizations need to perform tests technicians consistently which might help in building right responses at the right time. Training alone cannot gain complete skills, regular test and assessments will improve overall reaction time during emergency situations.

Failure in Implementing Appropriate Procedures and Processes:

Companies have to look at the processes and procedures are moving on right schedule and yielding good results. Companies need to have a regular update on formal set of procedures and processes which return maximum efficiency. Some of the procedures include EOP (Emergency Operational Procedure), Emergency response, Standard Operational Procedure, vendor management and Method of procedure.

Failure in Using Software Management Tool:

Most of the data center organizations neglect to install software management tools to minimize the operational cost. This seems cost effective. When a company starts catering more number of customers, management team might be at risk because of poor document management.

Failure in Implementing Quality Systems:

Data center need to implement efficient, cost effective and reliable hardware. One of the best ways to ensure proper quality of the systems is by including a Quality Assurance team.

These are the main steps need to be maintained to gain maximum efficiency of the facility.

Data Center Talk updates its resources everyday. Visit us to know of the latest technology and standards from the data center world.

Please leave your views and comments on DCT Forum

Share on TwitterSubmit to StumbleUpon

Reasons to Renovate Your Data Centers

               Most of the data centers have following features false floors, windowless rooms, lots of electrical outlets, limited walking space and sterile. Data Center renovations one of the best paths where managers can improve performance and improve the overall efficiency of the center. By renovating Data centers, managers can yield a lot of improvements in terms of space, performance, operating cost and many others. When do managers know it’s time to renovate data centers?  These following points will give some idea.

               One of the main goals of data centers is to maintain cool temperature. Whenever you traverse inside the data center, if you get any hot flashes or when temperature fluctuates greatly. Then it’s time to check and renovate the cooling system. CFD (Computational Fluid Dynamics) is one of the gauges which tell how to manage cooling systems in your data centers.

               Each and every day technology keeps on upgrading.  Have a look at technologies running in the current market and implement those in order to gain more efficiency.  Implement new rack designs which provide a new level of savings in cost and energy and also improves the level of control over data center.

               No room to add more servers? When you think of adding a new rack of sever to gain more power into your data center, you think of renovation. Carefully analyze servers and remove the servers which are not running, this might cause under utilization of resources and might directly affect your operations and maintenance cost.

               A fan is one of the cheapest cooling agents in data centers. A fan is capable of redirecting hot air away from servers and allows cool air inside the servers; this can reduce hot air between servers the data centers.

               When your data center looks like a room of cables. This means data center needs renovation and management team has to improve cabling. This might money and time and this leads to overall improvement of the data center.

               Worrying about natural disasters? We are not sure when data

center might be struck with a flood or earth quake and other emergencies.  New data center designs concentrate more on disaster management and recovery, implementing any of these designs might help to overcome disasters.

               Managers need to have a close look at data center Infrastructure management tools and these approaches might be worth of looking into. DCIM tools favor small data centers which are scalable.

                Not getting expected efficiency from your data centers? If you think that you are not yielding expected efficiency from your data centers, then it’s time to renovate your data center. While renovating data centers look for alternative energy sources and alternative source for cooling your servers.  Managers need to make a regular survey on servers and eliminate redundant hardware which might eat up a lot of energy.

                Renovating a data center is far more complex than renovating a house. In data centers renovation is a continuous process. Renovation process is a critical issue which minimizes the risk of downtime and also enhances the overall efficiency of the plant.

Data Center Talk updates its resources everyday. Visit us to know of the latest technology and standards from the data center world.

Please leave your views and comments on DCT Forum

Share on TwitterSubmit to StumbleUpon

Is Modular Design for Data Center Right Choice for Future?

Modular design for data centers is a current hot topic in IT industry. Companies are struggling to meet IT need and maintain efficiency. If data center companies choose to include modular design, then they have to select pod or containerized design. Modular design will provide flexibility to data centers. Some of the benefits enjoyed by modularized data centers are:

 Speed:

Modular Data Centers can be built 75% faster than conventional data centers.

Efficiency:

In Modular Data Centers hardware can be addressed incrementally, rather than immediate constructing entire data center space. In Dell data center solution engineering team are working hard to optimize entire data centers to reduce operational cost.

Flexibility:

Modular Data Centers are designed with standardized infrastructure which enables data centers to use operating system universally. This design will allow designers for easy replacement of hardware and operating system. A truly modular data center is either incrementally constructed or uses containerized solution.

 

Altering a traditional data center to Modula Data Center is similar to constructing a new facility with blocks of buildings, so it’s preferred to implement containerized approach in such conditions. Now let us have a close look

about POD design of data centers and Containerize solution

Pod Design for Data Centers:

In pod design data center consist of IT room, a supporting infrastructure room and IT computer room.  Supporting Infrastructure room includes mechanical and electrical room which provide power, cooling to IT computer room. Later design engineers can include any number of IT computer room based on their load requirements.

Instead of supplying space, power and cooling for an over build data centers at 50% efficiency rate, companies can divide data centers into small pods. Let us have an example, suppose a company with 10,000 sq ft area, companies can estimate a facility based on requirement and build a small pod of 1000 sq ft of storage and server equipment. Company can include adjutant pods based on IT requirements by following “pay as you grow” approach. This approach can lower the overall operating expenses and also increase the efficiency of the data center.

Containerized Solution for Data Centers:

Instead of designing a pod design from scratch companies can choose containerized solution, if company is ready to build, relocate or expand its facility. By following this containerized solution companies can lower their operating and capital cost, companies can also be benefited by avoiding local building techniques and codes. Cooing systems and airflow to servers can be engineered before implementing in the plant to optimize efficiency and performance. Containerized data centers can cut down deployment time from one year to weeks. Containerized data centers are best suited for remote locations. Containerized solutions gain more points in terms of mobility, containers can be placed anywhere and all containers will be pretested before deploying to the centers. Containerized solution can also be used as temporary solution when companies have expansion plan or when data centers come across any disaster. Apart from all these Containerized solution will provide multi-location support and high redeployment capabilities.

Before selecting any of the two modular design, it’s better to have a look at advantages and disadvantages of the two designs.

 

Pod Design

Containerized Solution

Flexible in size

Equipments must go in pre-fabricated containers

Canbe modified based on requirements

Newly configured containers must be deployed

Space can be designed for comfortable services

Uncomfortable and offers limited space for technicians

With proper design maximum efficiency can be achieved

Designers need to spend significant amount of dollars to improve efficiency

Permanent solution

Best suited for temporary needs

Initially takes at least 6 months later inclusion can happen more rapidly

Can be deployed within weeks

Must follow local building codes

Must follow ISO complaints

 

Data Center Talk updates its resources everyday. Visit us to know of the latest technology and standards from the data center world.

Please leave your views and comments on DCT Forum

Share on TwitterSubmit to StumbleUpon

Ways to Reduce Water Consumption in Data Center

All data center management teams have been thinking about conserving renewable energies, but recently data centers are concentrating more on conserving water. Saving any amount of water saves money, because water in short as it’s mostly used in domestic purposes. Data centers require an enormous amount of water to cool cloud computing server farms. James Hamilton Data Center Designer and Researcher in Amazon estimates Data centers with a capacity of 15 Mega Watt can utilize up-to 360, 000 gallons of water per day. Hamilton added, “Water is tomorrow’s big problem, no one talks about water. The water consumption (in data centers) is super embarrassing. It just doesn’t feel

responsible. We need designs that stop using water.”

          Google and Microsoft are adopting new alternative methods to cool their massive data centers. Companies are using water from nearby rivers canals and also using recycled water. Microsoft recently added a new Data center in San Antonio because local water company can provide large quantity of recycled water; this would have less impact on city’s drinking water. In Belgium Google installed a new data center next to Industrial canal, data center can draw water to cool massive servers using industrial water and can draw water from wells and rain water. Google has designed a new cooling system and they have named it as “Hot Huts”. These Hot Huts are temporary homes for hot air which leaves main servers. Fans are installed on these huts will pull hot air from behind the servers and lead them to water cooled coil, these ambient hot air from the servers. These fans will help to cool the air by leading them to water cooled coils and thus completing the cooling cycle.

One of the best methods to conserve water is by re-cycling it. Google’s data center in Hamina, Finland uses sea water to cool servers without using any chillers. This data center is located in Gulf of Finland. Cooling systems pump cold water from sea and heat from servers are exchanged. This ambient hot water is cooled before returning to gulf. Another Google’s data center in Douglas County uses city waste water to cool its servers. In this data center large tanks are filled with this water and fin sand particles are filtered out and leaving clear water to cool its servers (this water is unsuitable for drinking purpose).

Data centers must maintain their cooling systems regularly to avoid excess consumption of water. All Data centers must implement such alternative methods to cool its massive servers to reduce water consumption.

Data Center Talk updates its resources everyday. Visit us to know of the latest technology and standards from the data center world.

Please leave your views and comments on DCT Forum

Share on TwitterSubmit to StumbleUpon

Data center efficiency-Is it size dependent?

Data centers for a long time have taken their own stand when questioned about the efficiency of operations. Some data centers follow the conventional methods of strategy implementation while the others take a different route. For example, Google has adopted custom built servers and batteries, Facebook uses a unique evaporative cooling method to save power, and Yahoo has adopted an outdoor cooling design.

Data centers can be generally divided into two primary classes based on size that is the large data centers and the small data centers. Large data centers have an inherent advantage in implementing energy efficient strategies as they can shift operations to another facility as and when the situation demands. It could be a failure in the data center or an expansion plan adhering to all energy saving norms.

“Large centers can operate at a higher risk of failure with the offset, but smaller data centers can’t do that as easily,” said Fluegeman, who specializes in facilities, power and cooling, and is also the principal engineer with PlanNet Consulting.

“It’s following the sun or the moon, because they can very easily shift their traffic to different locations depending on whether it’s night or day in a particular location,” he said. “Especially if you’re using outside air and free cooling or air-side economy as it’s called, this is a concept that’s used to some degree by larger companies with data centers worldwide, where they shift traffic.”

In the case of smaller data centers (data centers that lack the infrastructure and resources of its larger counterparts) energy efficiency strategy implementation along with reducing costs is a difficult task.

So how does one cope with such a scenario?

According to Fluegeman, three quintessential parameters to be followed by a small data center are-

Design of the IT structure: it is essential to design the data center in a way that it helps in consolidation of the files. For example using file duplication or compression. This would automatically reduce the amount of space required for the storage of files. Enterprises can modify or make alterations to the network configurations from their own data centers as well as allowing the users to access data from anywhere at any time.

“There are ways to architect your system to deal with duplication and keep things lean and mean and trim with good housekeeping,” he said. “This allows data centers to be smaller and greener by using as little power as possible.”

Tiered storage can be used as another remedial measure: with this files are stored in servers, and the servers run on sleep mode. The files can be pulled up or retrieved only when necessary, thus saving a lot of power.

Restructuring the cooling method: It is imperative that small scale enterprise data centers make use of hot and cold aisle containment for data center cooling. This is to ensure that hot air is isolated from the cold air. But the crucial aspect of this design is to keep the hot air from nixing with the cold air. This would create a 30 degree difference in the temperature of the data center, says Fleugeman.

One way is to line up the servers such that the front faces one direction and the exhaust side faces the back. This forms the hot aisle and the cold aisle. Another way of doing this, in case of parallel arrangement of servers is to stack servers with alternate hot and cold aisles. Front faces of two servers face each other while the back faces the front of another line of servers

Use uninterrupted power supply to reduce excessive power costs: The use of the UPS is a radical transformation in the deployment of energy efficient measures. UPS is normally used when there is a power outage, but this can be prove to be an advantage for data centers as UPS wakes up from the sleep mode only when the power fails.

The difference in power drop and the UPS turning back on is so minimal that the equipments fail to pick up the drop in power and continue to operate continuously.

Switching to higher voltage equipments can result in a lot of power savings since it is more efficient and the physical conductors are smaller.

“If you look at power lines on big poles on the hill side, those wires are small- they’re far apart, but the power voltage is very high,” he said. “This is being applied to data centers now. Higher voltage is slightly more dangerous and in the U.S we have a lot more attorneys. That’s what keeps voltage lower, in my personal opinion.”

 

Data Center Talk updates its resources everyday. Visit us to know of the latest technology and standards from the data center world.

Please leave your views and comments on DCT Forum

Share on TwitterSubmit to StumbleUpon

PRACTICES TO ENSURE A MORE RELIABLE DATA CENTER

A data center is the core operating point of any IT infrastructure. Data centers house an enormous amount of information, which makes it all the more important to have a regular maintenance procedure. Daily routine checkup, as well as maintenance guidelines at regular intervals can help the data centers exercise efficiently.

Recent analyses by Gartner have proven that organizations these days look for more redundant data center solutions. Business agility is pushing these businesses to look for means that provide for a reliable and high performing data center. This in turn would enable them to frame data centers according to business needs.

Prepare and repair: If there is an existing data center that needs improvements, make the necessary changes to have a greater technological impact on the organization as a whole.

Target the ‘nothing’: Every organization consists of staggering number of equipments, operating systems, and hardware. Data centers which are a few years old have equipments and hardware that consume a lot of energy. Some data centers still house systems which do not help in operations, but create a cost many times more to operate than it is worth. Creating methods for the removal, replacement for such hardware is the best start towards reliability.

Rationalize the data center network: many organizations show certain amount of disparity between their core services and data centers. Data centers are not given the right amount of consideration that they deserve. It is important that the IT designers take the help of the experts for designing of a data center. It should be ensured that the data center is built according to the current design models. This should include support for wide-area network (WAN), network-attached storage (NAS), local-area network (LAN) and storage-area network (SAN) resources. The four elements used in characterization of the Tier data centers should be borne in mind. Design the data centers keeping in mind the current requirements and the future prospects. Follow industry standards to optimize cabling and networking efficiency.

Be energy and eco friendly: Take the help of the experts and analyze if your data center is running at optimum energy. If not, deploy measures such as advanced passive containment options for airflow, cabling and cooling that will streamline efficiency, maximize usage of current capacity and better manage the data center environment. Uninterruptable Power Supply (UPS) efficiency, passive cooling containment and various free-cooling options should all be considered.

Move to the cloud: Leverage cloud based technologies to offset cost, and also to deliver reliable IT services in the shortest possible duration with more uptime. This is definitely something that has to be on top of any IT manager’s list of priority.

The reality is that every IT organization has some type of traditional infrastructure- and software-delivery models they must contend with, but that doesn’t mean you can’t look for ways to improve performance. Logicalis, for example, has created a consulting framework to help clients determine what’s most essential and how to best shape a roadmap to drive toward a leaner delivery model that uses cloud technology to meet their specific business requirements.

Data Center Talk updates its resources everyday. Visit us to know of the latest technology and standards from the data center world.

Please leave your views and comments on DCT Forum

Share on TwitterSubmit to StumbleUpon

Data Center Management – Solutions to mitigate most Common Risks

 

Organizations today heavily depend on IT to support all their activities. This is why data centers have become a go-to facility for maintaining network and system functions. Customers too expect nothing but the best. This is why it is crucial to maintain a high performance service. Managing this infrastructure effectively is the key to enhanced operation rates. That is why data center managers should be able to track and assess the performance of individual sections of the data center effectively. Providing them with industry specific products should help them measure performance efficiently and mitigate potential risks. Let us look at these performance measurement products/tools and find out what they can do for the data center.

Availability of IT Equipment:

Downtime is data center manager’s worst nightmare. Generally customers expect system availability almost 100% of the time. Hence, IT personals need to access the reliability of the equipments of the data center so that that can reduce downtime considerably. The data obtained from assessing the equipments should also help them identify and alleviate issues.

Solution:

Technology has provided monitoring solutions which are based on the changing environmental factors and offers real time feedback about systems responding to factors like temperature, amperage draw, humidity, dew point, and physical security. These readings help the experts set thresholds for different atmospheric conditions. Additionally, this system also provides past information which can alert the personnel about the changing trends so that they are equipped with practices for that event.

Assessing Critical Services

Critical services means determining, classifying and rating the highest priority sites and facilities.  Systems like the four tiered classification system which is based on factors like useable capacity, fault tolerance, maintainability and sustainability helps in the evaluation .After undergoing the process, the administrators should be able to employ suitable managements and control systems for these critical sites which will help them mitigate potential vulnerabilities.

Solution:

Management solutions like KVM or service processor aggregation appliances offer the IT administrators access to servers, devices and even to equipments which are available locally and remotely. These provide BIOS – level access and offer assistance to reduce downtime by allowing instant access to all failed resources and data center management. These solutions also provide analysis and audit logging which helps the personnel gain valuable insight to the daily occurrence of the various operations in the data center.

Measuring the Data Center’s Energy Consumption

The rising rate of energy consumption is a cause of concern for most organizations. This has been a prime concern since companies are employing high density server racks which consume significant amount of energy. Experts are always looking for methods and practices to reduce the energy usage and making the data centers much more efficient. Proposition of implementing PUE and the DCE metrics should enable the data center managers estimate the efficiency of that data center. As Per Gris Grid which is consortium of IT companies, Power Usage Effectiveness (PUE) = Total Facility Power/ IT Equipment Power; Datacenter Efficiency (DCE) = IT Equipment Power/ Total Facility Power.  The PUE results are compared to different data centers to find out if the data center needs improvements to increase its efficiency.

Solution:

By using the results of PUE and DCE, administrators can evaluate the efficiency of their data center. Other than these, one can also use application specific data for evaluation. Performance rating tools like EPA energy star and Portfolio manager offers rating to the data center after comparing the results with other data centers. Switching to higher voltage power is also a practice which allows the IT equipment to operate much more efficiently. Regular audits of the facility including the racks and equipment will provide valuable insights like if the under the floor plan should be improved  or if some servers should be discarded. Using blanking panels and cable management accessories in the rack can also assist in reducing the energy usage of the data center making them energy efficient.

Data Center Talk updates its resources everyday. Visit us to know of the latest technology and standards from the data center world.

Please leave your views and comments on DCT Forum

Share on TwitterSubmit to StumbleUpon

SUSTAINABLE DATA CENTER PRACTICES

Environmental stewardship, innovation and leadership are becoming increasingly important as we take steps to create a sustainable environment for future generations. This is particularly important when it comes to construction of new data centers or major renovations of older ones.

The Leadership in Energy & Environmental Design (LEED) certification process offers a useful framework for organizing green strategies. To earn LEED certification, data centers must exhibit environmental responsibility in seven areas:

  • Sustainable sites
  • Water efficiency
  • Energy and atmosphere
  • Materials and resources
  • Indoor environmental quality
  • Innovation and design
  • Regional credits

Limiting physical sprawl is one of the most important goals of sustainable site development. Companies can reduce the amount of space their data centers occupy by deploying compact infrastructure resources. For example, many late-model uninterruptible power system (UPS) products feature footprints as much as 50 to 60 percent smaller than previous-generation models. Similarly, companies that operate their data center at 400V can eliminate transformer based Power Distribution Unit (PDU) cabinets, reducing their power distribution footprint by 50 to 60 percent.  Within the mechanical operations, using commercially packaged air handling units and In Row cooling (where needed) can eliminate traditional Computer Room Air Conditioners (CRACs) which take up significant space within many data halls.

Organizations can further promote sustainable site development in their new and existing data centers by embracing practices like the following:

  • Locating new facilities in existing industrial zones instead of on undeveloped land
  • Installing electric vehicle charging stations in the parking lot
  • Minimizing pollution during construction by controlling soil erosion, waterway sedimentation and airborne dust generation.
  • Providing easy access to public transportation, bicycle racks and changing rooms
  • Limiting parking capacity to the minimum mandated under local zoning regulations
  • Reducing light pollution by automatically shutting off interior lights during late-night hours and providing external lights only as required for safety and comfort

There are many sound reasons for wanting a greener data center, realizing that goal cost effectively is easier said than done. Just the same, most organizations can benefit from at least some green strategies without compromising corporate growth or IT reliability.

Some sustainability strategies, such as using recycled water, are still experimental, require heavy upfront investments or come with significant potential drawbacks. Most, however, are proven, cost-effective and relatively simple.